8. To verify if Disk is really failed or still usable, you can try to power on the
Disk. To power on Disk in Slot#1 of Enclosure#1, select “Rescue Raid Set”.
In the “Enter The Keyword” box, type “PowerOnDisk”, press space bar, and
then type “Enclosure#1 Slot#1”. The contents of “Enter The Keyword” box will
become “PowerOnDisk Enclosure#1 Slot#1”. Tick “Confirm The Operation”
and click “Submit”.
NOTE: Sometimes the “PowerOnDisk” command will need to wait
for several seconds before command execution is completed (web
GUI is updated), specially when the Raid subsystem is active or
busy.