FIBRE-to-SAS/SATA RAID SUBSYSTEM
158
User Manual
6. Upgrade Expander Firmware
a. Click menu "Administration > Service Options > Controller Services >
Upgrade Controller >".
b. Select “All Files” in File Type option, then choose the expander firmware file
v389.s3r.
NOTE: Upgrading could take several minutes to complete. It is
recommended to stop all access to the system and it takes around
4 minutes to upgrade each expander on the background.
NOTE: .bin image file can be used only when upgrading the
Expander’s firmware via RS232 while .s3r image file can be used
only when upgrading the Expander’s firmware via proRAID
Manager.
c. Double check if the new Expander Firmware is already displayed in the
Expanders table in Monitoring Æ System Information.
7. Power off the RAID subsystem. Power on after several seconds.
8. Upgrade Controller Firmware to Web GUI version 1.30.
a. Click menu "Administration > Service Options > Controller Services >
Upgrade Controller >".
b. Warning message will be displayed. Click “Yes” to start upgrade process which
takes several minutes.
c. Select the controller firmware binary file (version 1.30).
d. When “Confirm Firmware Details” message box is displayed, select “Yes” to
confirm upgrade.
e. Upgrade process will start. Verify if new firmware 1.30 is downloaded
successfully.